ISO 9001:2015
Modern means of measuring equipment
 

Thermocouples

Production:
WIKA (Germany)

a Thermocouple is a temperature sensor, whose output is directly removed, the voltage signal proportional to the temperature. It does not require additional power source, since the output voltage arises due to the thermoelectric properties of metals. Depending on temperature there are different types of thermocouples. Firm WIKA manufactures thermocouples with direct cable outlet and the terminal protective cap.

Normalizing current transformer can be installed directly in the head. To connect to the secondary electronic equipment (controller, indicator, Registrar, etc.), you must use a special cable with thermoelectric compensation.

Thermocouples are used at temperatures from -100 °C to +1500 °C (depending on the type of device, the type of thermocouple and materials coming into contact with measured medium.

Thermocouple type TC10

Production:
WIKA (Germany)
Thermocouple type TC10
  • Application:mechanical engineering,processing industry, storage tanks, energy, chemical industry,food industry;
  • Features:application Range from 0 to 1200°C, explosion proof versions Ex i and NAMUR NE24;
  • measuring Range: 0...1200 °C;
  • The sensing element:Type K, J, E, N, T;
  • process connection: G¼, G½, M20×1.5, M18×1,5 ;
  • Electrical connection: M20×1,5;

Thermocouple type TC12-B

Production:
WIKA (Germany)
Thermocouple type TC12-B
  • Application: Chemical industry, petrochemical industry, production of industrial plants and shipbuilding;
  • Features: For many variants of temperature transmitters with field Converter, for installation in any protective sleeve of conventional design, a spring-loaded measuring insert (exchangeable), explosion proof execution Ex d, Ex i;
  • measuring Range: -40...1200 °C;
  • The sensing element:Type K, J, E, N, T;
  • process connection: G¼, G½, M20×1.5, M18×1,5 ;
  • Electrical connection: M20×1,5;

Thermocouple type TC40

Production:
WIKA (Germany)
Thermocouple type TC40
  • Application:mechanical engineering, engines, power plants, temperature measurement of bearings, pipelines and tanks;
  • Features:application Range from 0 to 1200°C, explosion proof versions Ex i and NAMUR NE24;
  • measuring Range: 0...1200 °C;
  • sensing element: Type K, J, E, N, T;
  • process connection: G½, M18×1,5;

Thermocouple type TC80

Production:
WIKA (Germany)
Thermocouple type TC80
  • Application: Blast furnace, blast furnace air heaters, annealing and thermal processes, waste recycling, biomass, hazardous waste incineration, and industrial installations for heating, thermal, electric power plants, reactors, manufacture of glass, porcelain, ceramics, cement and brick ;
  • Features: application Range up to +1600 °C (DIN EN 50 446), a protective sleeve made of heat-resistant steel or ceramic, also with ceramic inner tube, support tube of carbon steel, gas-tight process connection coating (optional);
  • measuring Range: -200...1600 °C;
  • sensing element: Type S, R, B, K, N, J;
  • process connection: G1/2, G3/4, G1, 1 ½NPT,M20 x 1.5, M27 x 2 ;
  • Electrical connection: M20×1,5;

Additional information